Reference • 4
4-9SV61656 Rev. A
Problem Remedy Page
DOUBLE DETECT
Machine Stops for Doubles that Aren’t There or Feeds Doubles
without Stopping
Double detect is
not turned ON.
Check double detect status. Double
detect icon will appear alongside
all items for which double detect is
ON.
Correct loading or job setup as nec-
essary.
Chapter
2
Double detect is
not correctly cali-
brated.
Run a trial piece whenever you load
a new batch of material to recali-
brate double detect. The new batch
might have sheets that vary slightly
in thickness from the old batch.